54. REOPTX
The cold start option controls the linear solver that is used by the branch-and-bound solver at each node of the solution tree when a previous solution is not present to use as a "warm start". The warm start option determines the solver to use when a previous solution does exist.
There are four possible settings for REOPTX:
REOPTX Value  | 
 Cold Start Solver  | 
0  | 
LINGO Decides – LINGO chooses the most appropriate solver.  | 
1  | 
Primal – The primal solver will be used exclusively.  | 
2  | 
Dual – The dual solver will be used exclusively.  | 
3  | 
Barrier – LINGO uses the barrier method, assuming you have purchased a license for the barrier solver. Otherwise, the dual solver will be used.  | 
In general, LINGO Decides will yield the best results. However, experimentation with the other options may be fruitful.